Details Chevron Down

IMI Heimeier Dynacon Eclipse heating circuit distributor 934010800
10 heating circuits
  • Application
  • underfloor heating systems
  • Function:
  • Individual room temperature control with actuator or thermostatic head
  • Automatic flow control
  • shut off
  • To fill
  • drain
  • Wash
  • vent
  • pressure class:
  • PM 6
  • Flow range:
  • The flow can be infinitely adjusted within the specified range: 30 - 300 l/h.
  • Factory setting 300 l/h.
  • Differential pressure (ΔpV):
  • Max. differential pressure:
  • 60kPa (
  • Min. differential pressure:
  • 30 – 150 l/h = 17 kPa
  • 150 – 300 l/h = 25 kPa
  • Temperature:
  • Max. operating temperature: 70°C
  • Minimum operating temperature: -5°C
  • Materials:
  • Distributor:
  • 1.4301 stainless steel
  • Connection fittings: brass, nickel-plated.
  • Thermostat upper section:
  • Brass
  • O-rings: EPDM
  • Valve disk: EPDM
  • Compression spring: stainless steel
  • Thermostatic insert: brass, PPS.
  • Spindle: Stainless steel spindle with double O-ring seal. The outer O-ring can be replaced under pressure.
  • Flow indicator:
  • Heat-resistant plastics and stainless steel. Brass. EPDM seals.
  • Filling, draining, flushing and venting device:
  • Brass, nickel-plated and plastic. EPDM seals.

Product Safety Chevron Down

Manufacturer
IMI Hydronic Engineering Deutschland GmbH
E-Mail
info.de@imi-hydronic.com
Address
Völlinghauser Weg
59597 Erwitte
Germany
** Average Wholesale Price